Ronan X90 Series Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Ronan X90 Series. Ronan X90 Series User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Instructions
and
Operating Manual
SERIES X90
POINT LEVEL MONITORS
POINT LEVEL MONITORS
SERIES X90
Instructions and Operating Manual
Customer’s Name ____________________
Customer’s P.O. No.
__________________
Ronan Job No. ______________________
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - SERIES X90

Instructions and Operating Manual SERIES X90 POINT LEVEL MONITORS POINT LEVEL MONITORS SERIES X90 Instructions and Operating Manual Custome

Pagina 2 - TABLE OF CONTENTS

Calculate the radiation field intensity at 12 inches from the surface of the vessel shown in Figure 3. Total distance = 12 + 2 + 10 = 24 inches Dose

Pagina 3 - 1.0 GENERAL DESCRIPTION

f) The area in the vicinity of the source must be posted with a radiation warning sign, if the radiation field is greater than 5 mr/hr at a distance

Pagina 4 - 4.0 FUNCTIONAL OPTIONS

After these preliminary services are performed, a person specifically licensed by the NRC or an agreement state must do the start-up of the gage. Thi

Pagina 5

11.9 Standard Sources SA-1, SA-8 11.9.1 ON/OFF mechanism: To test the ON/OFF mechanism, move the handle back and forth several tim

Pagina 6

12.0 LEAK TEST PROCEDURES FOR SEALED SOURCES 12.1 Ronan Leak Testing Service The NRC requires that all sealed sources be tested for leak

Pagina 7 - 11.0 RADIATION SAFETY

PARTS LIST—SERIES X90 POINT LEVEL MONITOR Item Qty. ID Part No. Description Vendor 12 4 350-1246-11-07- Terminal Cambion 13 2 Spacer

Pagina 8

PARTS LIST—SERIES X90 POINT LEVEL MONITOR Item Qty. ID Part No. Description Vendor 23 24 3 R27,33,34 RC07GF104J Resistor, Carbon

Pagina 9 - 9

PARTS LIST—SERIES X90 POINT LEVEL MONITOR Item Qty. ID Part No. Description Vendor 63 2 Relay Holdown Potter & Brumfield 64

Pagina 10

PARTS LIST—SERIES X90 POINT LEVEL MONITOR Item Qty. ID Part No. Description Vendor 20 1 R23 RN55C1001 Resistor, M.F., ¼ W, 1%, 1 k M

Pagina 11

PARTS LIST—SERIES X90 POINT LEVEL MONITOR Item Qty. ID Part No. Description Vendor 64 1 IC2 7906C Voltage Regulator, 6 V Motorola 65

Pagina 12

TABLE OF CONTENTS 1.0 2.0 3.0 4.0 4.1 4.2 4.3 5.0 5.1 6.0 7.0 7.1 7.2 7.3 8.0 9.0 9.1 9.2 9.3 9.4 10.0 11.0 11.1 11.2 11.3 11.4 11.5 11.6 11.7 11.8

Pagina 14

1.0 GENERAL DESCRIPTION The Ronan Series X90 Point Level Monitor economically and reliably solves many process problems in which noise, temperature,

Pagina 15

Time Delay Range: Integral: 0.5 to 20 seconds (10 or 20 seconds normal); jumper-selectable Remote: .05 to 20 seconds (10 or 20 seconds normal); jum

Pagina 16

the tube output does not indicate a minimum background value (due to a malfunction in the G-M tube or its power supply) the process (and failure, if u

Pagina 17

module is not necessary in order to change wiring. Grommeted holes are provided on the top and bottom surfaces of the chassis for cable entry and exi

Pagina 18

10.0 TROUBLESHOOTING The X90 is constructed to require the minimum of maintenance. Operated properly, it should not require any maintenance for a c

Pagina 19

In the majority of Ronan installations, the source is contained in a lead-filled source holder with an ON/OFF mechanism. The holder is designed so th

Pagina 20

9 Figure 2: Radiation Transmission CS-137 for Various Materials